344 research outputs found

    An Analysis by Synthesis Approach for Automatic Vertebral Shape Identification in Clinical QCT

    Full text link
    Quantitative computed tomography (QCT) is a widely used tool for osteoporosis diagnosis and monitoring. The assessment of cortical markers like cortical bone mineral density (BMD) and thickness is a demanding task, mainly because of the limited spatial resolution of QCT. We propose a direct model based method to automatically identify the surface through the center of the cortex of human vertebra. We develop a statistical bone model and analyze its probability distribution after the imaging process. Using an as-rigid-as-possible deformation we find the cortical surface that maximizes the likelihood of our model given the input volume. Using the European Spine Phantom (ESP) and a high resolution \mu CT scan of a cadaveric vertebra, we show that the proposed method is able to accurately identify the real center of cortex ex-vivo. To demonstrate the in-vivo applicability of our method we use manually obtained surfaces for comparison.Comment: Presented on German Conference on Pattern Recognition (GCPR) 2018 in Stuttgar

    Magnification, dust and time-delay constraints from the first resolved strongly lensed Type Ia supernova

    Get PDF
    We report lensing magnifications, extinction, and time-delay estimates for the first resolved, multiply-imaged Type Ia supernova iPTF16geu, at z = 0.409, using Hubble Space Telescope (HST) observations in combination with supporting ground-based data. Multi-band photometry of the resolved images provides unique information about the differential dimming due to dust in the lensing galaxy. Using HST and Keck AO reference images taken after the SN faded, we obtain a total lensing magnification for iPTF16geu of μ = 67.8^(+2.6)_(−2.9), accounting for extinction in the host and lensing galaxy. As expected from the symmetry of the system, we measure very short time-delays for the three fainter images with respect to the brightest one: -0.23 ± 0.99, -1.43 ± 0.74 and 1.36 ± 1.07 days. Interestingly, we find large differences between the magnifications of the four supernova images, even after accounting for uncertainties in the extinction corrections: Δm_1 = −3.88^(+0.07)_(−0.06), Δm_2 = −2.99^(+0.09)_(−0.08), Δm_3 = −2.19^(+0.14)_(−0.15) and Δm_4 = −2.40^(+0.14)_(−0.12) mag, discrepant with model predictions suggesting similar image brightnesses. A possible explanation for the large differences is gravitational lensing by substructures, micro- or millilensing, in addition to the large scale lens causing the image separations. We find that the inferred magnification is insensitive to the assumptions about the dust properties in the host and lens galaxy

    Detectability of motions in AAA with ECG-gated CTA: A quantitative study

    Get PDF
    Purpose: ECG-gated CT enables the visualization of motions caused by the beating of the heart. Although ECG gating is frequently used in cardiac CT imaging, this technique is also very promising for evaluating vessel wall motion of the aortic artery and the motions of (stent grafts inside) abdominal aortic aneurysms (AAA). Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion characteristics of stent grafts will be beneficial for designing future devices. In addition, these data can be valuable in predicting stent graft failure in patients. To be able to reliably quantify the motion, however, it is of importance to know the performance and limitations of ECG gating, especially when the motions are small, as is the case in AAA. Since the details of the reconstruction algorithms are proprietary information on the CT manufacturers and not in the public domain, empirical experiments are required. The goal of this study is to investigate as to what extent the motions in AAA can be measured using ECG-gated CT. The authors quantitatively investigate four aspects of motion in ECG-gated CT: The detectability of the motion of objects at different amplitudes and different periodic motions, the temporal resolution, and the volume gaps that occur as a function of heart rate.\ud \ud Methods: They designed an experiment on a standard static phantom to empirically determine temporal resolution. To investigate motion amplitude and frequency, as well as patient heart rate, they designed dynamic experiments in which a home-made phantom driven by a motion unit moves in a predetermined pattern.\ud \ud Results: The duration of each ECG-gated phase was found to be 185 ms, which corresponds to half of the rotation time and is thus in accordance with half scan reconstruction applied by the scanner. By using subpixel localization, motions become detectable from amplitudes of as small as 0.4 mm in the x direction and 0.7 mm in the z direction. With the rotation time used in this study, motions up to 2.7 Hz can be reliably detected. The reconstruction algorithm fills volume gaps with noisy data using interpolation, but objects within these gaps remain hidden.\ud \ud Conclusions: This study gives insight into the possibilities and limitations for measuring small motions using ECG-gated CT. Application of the experimental method is not restricted to the CT scanner of a single manufacturer. From the results, they conclude that ECG-gated CTA is a suitable technique for studying the expected motions of the stent graft and vessel wall in AAA.\u

    Magnification, dust and time-delay constraints from the first resolved strongly lensed Type Ia supernova iPTF16geu

    Get PDF
    We report lensing magnifications, extinction, and time-delay estimates for the first resolved, multiply imaged Type Ia supernova iPTF16geu, at z = 0.409, using Hubble Space Telescope (HST) observations in combination with supporting ground-based data. Multiband photometry of the resolved images provides unique information about the differential dimming due to dust in the lensing galaxy. Using HST and Keck AO reference images taken after the SN faded, we obtain a total lensing magnification for iPTF16geu of μ = 67.8^(+2.6)_(−2.9)⁠, accounting for extinction in the host and lensing galaxy. As expected from the symmetry of the system, we measure very short time-delays for the three fainter images with respect to the brightest one: −0.23 ± 0.99, −1.43 ± 0.74, and 1.36 ± 1.07 d. Interestingly, we find large differences between the magnifications of the four supernova images, even after accounting for uncertainties in the extinction corrections: Δm₁ = −3.88^(+0.07)_(−0.06), Δm₂ = −2.99^(+0.09)_(−0.08)⁠, Δm₃ = −2.19^(+0.14)_(−0.15)⁠, and Δm₄ = −2.40^(+0.14)_(−0.12) mag, discrepant with model predictions suggesting similar image brightnesses. A possible explanation for the large differences is gravitational lensing by substructures, micro- or millilensing, in addition to the large-scale lens causing the image separations. We find that the inferred magnification is insensitive to the assumptions about the dust properties in the host and lens galaxy

    Radiation exposure in X-ray-based imaging techniques used in osteoporosis

    Get PDF
    Recent advances in medical X-ray imaging have enabled the development of new techniques capable of assessing not only bone quantity but also structure. This article provides (a) a brief review of the current X-ray methods used for quantitative assessment of the skeleton, (b) data on the levels of radiation exposure associated with these methods and (c) information about radiation safety issues. Radiation doses associated with dual-energy X-ray absorptiometry are very low. However, as with any X-ray imaging technique, each particular examination must always be clinically justified. When an examination is justified, the emphasis must be on dose optimisation of imaging protocols. Dose optimisation is more important for paediatric examinations because children are more vulnerable to radiation than adults. Methods based on multi-detector CT (MDCT) are associated with higher radiation doses. New 3D volumetric hip and spine quantitative computed tomography (QCT) techniques and high-resolution MDCT for evaluation of bone structure deliver doses to patients from 1 to 3 mSv. Low-dose protocols are needed to reduce radiation exposure from these methods and minimise associated health risks

    Совершенствование системы подбора и отбора персонала предприятия

    Get PDF
    Объектом исследования является действующая система подбора и отбора персонала на предприятии АО "НПЦ "Полюс". Предметом исследования является совершенствование действующей системы подбора и отбора персонала на предприятии АО "НПЦ "Полюс". Цель работы – разработка рекомендаций по совершенствованию системы подбора и отбора персонала на предприятии АО "НПЦ "Полюс". Задачи: 1)рассмотреть понятие подбора и отбора персонала на предприятии; 2)дать краткую характеристику деятельности предприятия; 3)дать характеристику персоналу предприятия; 4)проанализировать действующую систему подбора и отбор персонала на предприятии; 5)выявить проблемы системы подбора и отбора персонала; 6)разработать рекомендации по совершенствованию подбора и отбора; 7)оценить эффективность от применения мероприятий.The object of research is the current system of selection and selection of personnel at the enterprise of JSC "Scientific and Production Center" Polyus ". The subject of the study is the improvement of the existing personnel selection and selection system at the enterprise of Polyus Scientific and Production Center JSC. The purpose of the work is to develop recommendations for improving the personnel selection and selection system at the enterprise of Polyus Scientific and Production Center JSC. Tasks: 1) to consider the concept of selection and selection of personnel in the enterprise; 2) to analyze the dynamics of the number, structure and movement of personnel; 3) to develop recommendations for improving the system of selection and selection of personnel in the enterprise